Найти в Дзене

Zabbix шаблон для сервера HP Proliant DL360 Gen9

Оглавление

Делюсь полезным шаблоном для мониторинга сервера  HP Proliant DL360 Gen9. Мониторим по IPMI. Шаблон делал сам.

В шаблоне 7 приложений, 80 элементов данных, 39 триггеров и 3 графика.

Zabbix 3.4.12.

Скачать шаблон: zbx_IPMI_HPDL360G9_v3.xml

Value mapping

Administration > General > Value mapping

IPMI Availability Status States

1 ⇒ Device Removed / Device Absent
2 ⇒ Device Inserted / Device Present

IPMI Availability Status States (0Ah)

1 ⇒ Transition to Running
2 ⇒ Transition to In Test
4 ⇒ Transition to Power Off
8 ⇒ Transition to On Line
16 ⇒ Transition to Off Line
32 ⇒ Transition to Off Duty
64 ⇒ Transition to Degraded
128 ⇒ Transition to Power Save
256 ⇒ Install Error

IPMI Battery

1 ⇒ Battery low (predictive failure)
2 ⇒ Battery failed
4 ⇒ Battery presence detected

IPMI Drive Slot (Bay)

1 ⇒ Drive Present
2 ⇒ Drive Fault
4 ⇒ Predictive Failure
8 ⇒ Hot Spare
16 ⇒ Consistency Check / Parity Check in progress
32 ⇒ In Critical Array
64 ⇒ In Failed Array
128 ⇒ Rebuild/Remap in progress
256 ⇒ Rebuild/Remap Abortes (was not complete normally)

IPMI Memory

1 ⇒ Correctable ECC
2 ⇒ Uncorrectable ECC
4 ⇒ Parity
8 ⇒ Memory Scrub Failed
16 ⇒ Memory Device Disabled
32 ⇒ Correctable ECC / other correctable memory error logging limit r
64 ⇒ Presence detected
128 ⇒ Configuration error
256 ⇒ Spare
512 ⇒ Memory Automatically Throttled
1024 ⇒ Critical Overtemperature

IPMI OEM LED UID

1 ⇒ On
2 ⇒ Off
4 ⇒ Blink

IPMI Power Supply

0 ⇒ Power supply not installed
1 ⇒ Presence detected
2 ⇒ Failure detected
4 ⇒ Predictive Failure
8 ⇒ Input lost (AC/DC)
16 ⇒ Input lost or out-of-range
32 ⇒ Input out-of-range but present
64 ⇒ Configuration error
128 ⇒ Inactive

IPMI Redundancy States

1 ⇒ Fully Redundant
2 ⇒ Redundancy Lost
4 ⇒ Redundancy Degraded
8 ⇒ Non-Redundant
16 ⇒ Non-Redundant
32 ⇒ Non-Redundant
64 ⇒ Redundancy Degraded
128 ⇒ Redundancy Degraded

IPMI Severity Event States

1 ⇒ Transition to OK
2 ⇒ Transition to Non-Critical from OK
4 ⇒ Transition to Critical from less severe
8 ⇒ Transition to Non-recoverable from less severe
16 ⇒ Transition to Non-Critical from more severe
32 ⇒ Transition to Critical from Non-recoverable
64 ⇒ Transition to Non-recoverable
128 ⇒ Monitor
256 ⇒ Informational

Приложения
Приложения
Power
Power
Fan Speed
Fan Speed

Источник:
https://internet-lab.ru/zabbix_template_hp_proliant_dl360_gen9

Если вам понравилась статья, то ставьте 👍🏻 каналу.
Пишите комментарии, задавайте вопросы, подписывайтесь.